EC 28i (Intrinscially Safe) Fixed Transmitter Series

Item Code: 129000
Wherever hazards are expected, the EC 28 transmitter and GfG's proven monitoring systems are the right choice for reliable surveillance. The ATEX-certified Ex-proof design, and bright alarm LEDs provide the highest safety in hazardous areas. The gas alarm not only alerts the person in the control room of hazards, but also the person on-site.
Smart sensor technology allows a user to install the transmitter or to replace a sensor within a few seconds - just plug the sensor into the transmitter. Adjustments are done directly at the transmitter using touch keys or with the RC2 remote control (one-person calibration).
Accurate sensors and integrated temperature compensation provide the highest measurement accuracy. Low maintenance requirements and the long sensor life reduce your cost of ownership.

• Increased safety design to reduce installation cost in potentially hazardous locations

• Non-intrusive AutoCal® calibration adjustment

• Uses electrochemical detection principle

• Output signal: 4-20 mA

• Intrinsically safe (i) EX-Proof

• ATEX II 1G EEx ia IIC T4 C 0158

• Available with digital measurement display (EC 28 Di) or blind, no display (EC 28i)
C2H4O, Cl2, ClO2, CO, CO-H, H2, H2S, HCl, HCN, NH3, NO, NO2, O2, O3, SO2.
Image Item Code
Options
Full Description 1 + Qty.
Transmitters (4)
EC 28Di transmitter w/ Hydrogen sulfide (H2S) - w/ display, 0 - 200 ppm
2813-720-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Hydrogen sulfide (H2S) - w/ display, 0 - 200 ppm
Compare
EC 28i transmitter w/ Chlorine (Cl2) - w/out Display, 0 - 50.0 ppm, requires RC2 Remote Control for calibration p/n 2800201
2813-709-001
Brand

GFG Instrumentation

UOM

EA

EC 28i transmitter w/ Chlorine (Cl2) - w/out Display, 0 - 50.0 ppm, requires RC2 Remote Control for calibration p/n 2800201
Compare
EC 28Di transmitter w/ Carbon monoxide (CO) - w/ Display, 0 - 500 ppm
2813-707-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Carbon monoxide (CO) - w/ Display, 0 - 500 ppm
Compare
EC 28Di transmitter w/ Oxygen (O2) - w/ display, 0 - 25.0% vol.
2813-727-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Oxygen (O2) - w/ display, 0 - 25.0% vol.
Compare
Replacement Sensors (4)
Replacement sensor for EC 28i, Hydrogen sulfide (H2S), 0 - 200  ppm
2810720-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Hydrogen sulfide (H2S), 0 - 200 ppm
Compare
Replacement sensor for EC 28i, Chlorine (Cl2), 0-50.0 ppm
2810709-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Chlorine (Cl2), 0-50.0 ppm
Compare
Replacement sensor for EC 28i, Carbon monoxide (CO), 0-500 ppm
2810707-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Carbon monoxide (CO), 0-500 ppm
Compare
Replacement sensor for EC 28i, Oxygen (O2), 0 - 25.0%  vol.
2810727-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Oxygen (O2), 0 - 25.0% vol.
Compare
Accessories (4)
RC2 - Remote Control required for calibration of blind transmitters; optional for transmitters w/ display & 6' connection cable
2800201-1
Brand

GFG Instrumentation

UOM

EA

RC2 - Remote Control required for calibration of blind transmitters; optional for transmitters w/ display & 6' connection cable
Compare
Connection cable (6') for RC2 Remote Control
2800210-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (6') for RC2 Remote Control
Compare
Connection cable (16') for RC2 Remote Control
2800211-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (16') for RC2 Remote Control
Compare
Connection cable (33') for RC2 Remote Control
2800213-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (33') for RC2 Remote Control
Compare
Calibration Kits and Accessories (5)
Calibration adapter w/ tubing for reactive gases & sample systems
2810-203-1
Brand

GFG Instrumentation

UOM

EA

Calibration adapter w/ tubing for reactive gases & sample systems
Compare
Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ outside thread (34 L steel) w/ case, fixed flow regulator, cal adapter & tubing
7771-034-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ outside thread (34 L steel) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/  Cl2) for cylinders w/ inside thread (103 L steel & all aluminum) w/ case, fixed flow regulator, cal adapter & tubing
7771-038-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ inside thread (103 L steel & all aluminum) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ blue blow-molded carrying case (for 58 & 103 L cylinders) & 0.5 lpm fixed flow regulator (2603-025) w/ case, fixed flow regulator, cal adapter & tubing
7771-035-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ blue blow-molded carrying case (for 58 & 103 L cylinders) & 0.5 lpm fixed flow regulator (2603-025) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ 1.0 lpm regulator (for use w/ Cl2) w/ case, fixed flow regulator, cal adapter & tubing
7771-040-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 1.0 lpm regulator (for use w/ Cl2) w/ case, fixed flow regulator, cal adapter & tubing
Compare

Specifications

Brand

GFG Instrumentation

Category

Gas Detection

EC 28i (Intrinscially Safe) Fixed Transmitter Series

Item Code: 129000
Wherever hazards are expected, the EC 28 transmitter and GfG's proven monitoring systems are the right choice for reliable surveillance. The ATEX-certified Ex-proof design, and bright alarm LEDs provide the highest safety in hazardous areas. The gas alarm not only alerts the person in the control room of hazards, but also the person on-site.
Smart sensor technology allows a user to install the transmitter or to replace a sensor within a few seconds - just plug the sensor into the transmitter. Adjustments are done directly at the transmitter using touch keys or with the RC2 remote control (one-person calibration).
Accurate sensors and integrated temperature compensation provide the highest measurement accuracy. Low maintenance requirements and the long sensor life reduce your cost of ownership.

• Increased safety design to reduce installation cost in potentially hazardous locations

• Non-intrusive AutoCal® calibration adjustment

• Uses electrochemical detection principle

• Output signal: 4-20 mA

• Intrinsically safe (i) EX-Proof

• ATEX II 1G EEx ia IIC T4 C 0158

• Available with digital measurement display (EC 28 Di) or blind, no display (EC 28i)
C2H4O, Cl2, ClO2, CO, CO-H, H2, H2S, HCl, HCN, NH3, NO, NO2, O2, O3, SO2.
Image Item Code
Options
Full Description 1 + Qty.
Transmitters (4)
EC 28Di transmitter w/ Hydrogen sulfide (H2S) - w/ display, 0 - 200 ppm
2813-720-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Hydrogen sulfide (H2S) - w/ display, 0 - 200 ppm
Compare
EC 28i transmitter w/ Chlorine (Cl2) - w/out Display, 0 - 50.0 ppm, requires RC2 Remote Control for calibration p/n 2800201
2813-709-001
Brand

GFG Instrumentation

UOM

EA

EC 28i transmitter w/ Chlorine (Cl2) - w/out Display, 0 - 50.0 ppm, requires RC2 Remote Control for calibration p/n 2800201
Compare
EC 28Di transmitter w/ Carbon monoxide (CO) - w/ Display, 0 - 500 ppm
2813-707-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Carbon monoxide (CO) - w/ Display, 0 - 500 ppm
Compare
EC 28Di transmitter w/ Oxygen (O2) - w/ display, 0 - 25.0% vol.
2813-727-002
Brand

GFG Instrumentation

UOM

EA

EC 28Di transmitter w/ Oxygen (O2) - w/ display, 0 - 25.0% vol.
Compare
Replacement Sensors (4)
Replacement sensor for EC 28i, Hydrogen sulfide (H2S), 0 - 200  ppm
2810720-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Hydrogen sulfide (H2S), 0 - 200 ppm
Compare
Replacement sensor for EC 28i, Chlorine (Cl2), 0-50.0 ppm
2810709-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Chlorine (Cl2), 0-50.0 ppm
Compare
Replacement sensor for EC 28i, Carbon monoxide (CO), 0-500 ppm
2810707-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Carbon monoxide (CO), 0-500 ppm
Compare
Replacement sensor for EC 28i, Oxygen (O2), 0 - 25.0%  vol.
2810727-1
Brand

GFG Instrumentation

UOM

EA

Replacement sensor for EC 28i, Oxygen (O2), 0 - 25.0% vol.
Compare
Accessories (4)
RC2 - Remote Control required for calibration of blind transmitters; optional for transmitters w/ display & 6' connection cable
2800201-1
Brand

GFG Instrumentation

UOM

EA

RC2 - Remote Control required for calibration of blind transmitters; optional for transmitters w/ display & 6' connection cable
Compare
Connection cable (6') for RC2 Remote Control
2800210-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (6') for RC2 Remote Control
Compare
Connection cable (16') for RC2 Remote Control
2800211-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (16') for RC2 Remote Control
Compare
Connection cable (33') for RC2 Remote Control
2800213-1
Brand

GFG Instrumentation

UOM

EA

Connection cable (33') for RC2 Remote Control
Compare
Calibration Kits and Accessories (5)
Calibration adapter w/ tubing for reactive gases & sample systems
2810-203-1
Brand

GFG Instrumentation

UOM

EA

Calibration adapter w/ tubing for reactive gases & sample systems
Compare
Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ outside thread (34 L steel) w/ case, fixed flow regulator, cal adapter & tubing
7771-034-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ outside thread (34 L steel) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/  Cl2) for cylinders w/ inside thread (103 L steel & all aluminum) w/ case, fixed flow regulator, cal adapter & tubing
7771-038-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 0.5 lpm regulator (not for use w/ Cl2) for cylinders w/ inside thread (103 L steel & all aluminum) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ blue blow-molded carrying case (for 58 & 103 L cylinders) & 0.5 lpm fixed flow regulator (2603-025) w/ case, fixed flow regulator, cal adapter & tubing
7771-035-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ blue blow-molded carrying case (for 58 & 103 L cylinders) & 0.5 lpm fixed flow regulator (2603-025) w/ case, fixed flow regulator, cal adapter & tubing
Compare
Calibration kit w/ out gas, w/ 1.0 lpm regulator (for use w/ Cl2) w/ case, fixed flow regulator, cal adapter & tubing
7771-040-1
Brand

GFG Instrumentation

UOM

EA

Calibration kit w/ out gas, w/ 1.0 lpm regulator (for use w/ Cl2) w/ case, fixed flow regulator, cal adapter & tubing
Compare